<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">zldm</journal-id><journal-title-group><journal-title xml:lang="ru">Заводская лаборатория. Диагностика материалов</journal-title><trans-title-group xml:lang="en"><trans-title>Industrial laboratory. Diagnostics of materials</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1028-6861</issn><issn pub-type="epub">2588-0187</issn><publisher><publisher-name>ООО «Издательство «ТЕСТ-ЗЛ»</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.26896/1028-6861-2020-86-9-5-13</article-id><article-id custom-type="elpub" pub-id-type="custom">zldm-1273</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>АНАЛИЗ ВЕЩЕСТВА</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>SUBSTANCES ANALYSIS</subject></subj-group></article-categories><title-group><article-title>Модифицированные планарные сенсоры для определения некоторых цефалоспориновых антибиотиков в биологических и лекарственных средах</article-title><trans-title-group xml:lang="en"><trans-title>Modified planar sensors for determination of some cephalosporin antibiotics in biological and medicinal media</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кулапина</surname><given-names>Е. Г</given-names></name><name name-style="western" xml:lang="en"><surname>Kulapina</surname><given-names>E. G.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Елена Григорьевна Кулапина</p><p>410012, Саратов, ул. Астраханская, 83</p></bio><bio xml:lang="en"><p>Elena G. Kulapina</p><p>112 Bol’shaya Kazach’ya ul., Saratov, 410012</p></bio><email xlink:type="simple">kulapinaeg@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кулапина</surname><given-names>О. И.</given-names></name><name name-style="western" xml:lang="en"><surname>Kulapina</surname><given-names>O. I.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Ольга Ивановна Кулапина</p><p>410012, Саратов, ул. Большая Казачья, 112</p></bio><bio xml:lang="en"><p>Olga I. Kulapina</p><p>112 Bol’shaya Kazach’ya ul., Saratov, 410012</p></bio><email xlink:type="simple">olgakulapina@mail.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Анкина</surname><given-names>В. Д.</given-names></name><name name-style="western" xml:lang="en"><surname>Ankina</surname><given-names>V. D.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Влада Денисовна Анкина</p><p>410012, Саратов, ул. Большая Казачья, 112</p></bio><bio xml:lang="en"><p>Vlada D. Ankina</p><p>112 Bol’shaya Kazach’ya ul., Saratov, 410012</p></bio><email xlink:type="simple">vlada.ankina@mail.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Орлов</surname><given-names>С. Б.</given-names></name><name name-style="western" xml:lang="en"><surname>Orlov</surname><given-names>S. B.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Сергей Борисович Орлов</p><p>410012, Саратов, ул. Большая Казачья, 112</p></bio><bio xml:lang="en"><p>Sergey B. Orlov</p></bio><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>Саратовский национальный исследовательский государственный университет им. Н.Г. Чернышевского</institution><country>Россия</country></aff><aff xml:lang="en"><institution>N.G. Chernyshevsky Saratov National Research State University</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Саратовский государственный медицинский университет им. В.И. Разумовского</institution><country>Россия</country></aff><aff xml:lang="en"><institution>V.I. Umumovsky Saratov State Medical University</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2020</year></pub-date><pub-date pub-type="epub"><day>13</day><month>09</month><year>2020</year></pub-date><volume>86</volume><issue>9</issue><fpage>5</fpage><lpage>13</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Кулапина Е.Г., Кулапина О.И., Анкина В.Д., Орлов С.Б., 2020</copyright-statement><copyright-year>2020</copyright-year><copyright-holder xml:lang="ru">Кулапина Е.Г., Кулапина О.И., Анкина В.Д., Орлов С.Б.</copyright-holder><copyright-holder xml:lang="en">Kulapina E.G., Kulapina O.I., Ankina V.D., Orlov S.B.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.zldm.ru/jour/article/view/1273">https://www.zldm.ru/jour/article/view/1273</self-uri><abstract><p>Экспрессное определение цефалоспориновых антибиотиков в биологических жидкостях необходимо для оценки физиологических и биохимических процессов, протекающих в организме. Разработаны планарные немодифицированные и модифицированные полианилином (0,3 – 1 %), наночастицами NiZnFeO и их бинарными смесями потенциометрические сенсоры различных типов на основе ассоциатов тетрадециламмония (ТДА) с комплексными соединениями серебро(I) — β-лактам, чувствительные к цефазолину (Cef), цефуроксиму (Cefur) и цефтриаксону (Ceftr). В сенсорах I типа электродно-активные компоненты (ЭАС) и модификаторы вносили в углеродсодержащие чернила, в сенсорах II типа использовали поливинилхлоридные пластифицированные немодифицированные и модифицированные мембраны на основе [Ag2(Ceftr)2]2 · 2ТДА. Оценены электроаналитические и операционные характеристики немодифицированных и модифицированных планарных сенсоров в водных растворах цефазолина, цефуроксима, цефтриаксона и на фоне ротовой жидкости. Показано, что введение модификаторов в углеродсодержащие чернила сенсоров приводит к стабилизации их потенциала, увеличению угловых коэффициентов электродных функций, снижению предела обнаружения антибиотиков до 1,7 · 10–5 моль/л, уменьшению времени отклика и дрейфа потенциала. Наиболее эффективным модификатором оказались наночастицы NiZnFeO. Для сенсоров II типа электродные функции линейны в интервале концентраций 3,1 · 10–5 – 0,1 · 10–1 моль/л цефтриаксона. В зависимости от содержания ЭАС в фазе мембран немодифицированных планарных сенсоров угловые коэффициенты электродных функций изменяются в пределах 25 – 27 мВ/pC и соответствуют нернстовским значениям для двузарядных ионов. Интервалы линейности электродных функций сенсоров идентичны при всех исследуемых концентрациях ЭАС; с увеличением CЭАС уменьшаются дрейф потенциала и время отклика. Разработанные планарные сенсоры использовали для определения цефалоспориновых антибиотиков в модельных водных растворах, лекарственных препаратах и ротовой жидкости.</p></abstract><trans-abstract xml:lang="en"><p>Pluripotential cephalosporin antibiotics of different generations active against Gram-negative bacteria are used when treating urinary tract infections, mild and moderate pyelonephritis, acute otitis in children, etc. Rapid determination of cephalosporin antibiotics in the biological fluids is important to evaluate physiological and biochemical processes resulting from their metabolism in a human organism. Planar potentiometric sensors of different types — unmodified and modified with polyaniline (0.3 – 1%), NiZnFeO nanoparticles, and their binary mixes — are developed on the basis of associates of tetradecylammonium (TDA) with complex compounds silver (I) — β-lactam [Ag (I) – (β-lac)2] which are sensitive to some cephalosporin antibiotics, i.e., cefazoline (Cef), cefuroksime (Cefur) and ceftriaksone (Ceftr). In the sensors of type I, electrode-active components (EAC) and modifiers were added to carbon-containing ink, whereas in type II sensors the polyvinylchloride plasticized unmodified and modified membranes based on [Ag2(Ceftr)2]2 · 2TDA were used. Electroanalytic and operational characteristics of unmodified and modified planar sensors in aqueous solutions of cefazoline, cefuroxime, ceftriaxone and against the background of oral fluid were estimated. It is shown that introduction of the modifiers into sensor membranes leads to stabilization of their potential, increases angular coefficients of electrode functions, decreases the antibiotic detection limit to 1.7 Ч 10–5 M, reduces the response time and potential drift. Nanoparticles of NiZnFeO appeared to be the most effective modifier. For the sensors of type II linearity of electrode functions is observed in the range of ceftriaxone concentrations of 3.1 Ч 10–5 – 0.1 Ч 10–1 M. Depending on the content of the electrode active components in the membrane phase of the unmodified planar sensors, the values of the angular coefficients of the electrode functions vary within 25 – 27 mV/pC and correspond to the values of the non-static value for doubly-charged ions. The linearity intervals of sensor electrode functions are identical at all EAC concentrations under study; as Ceas increases, potential drift and response time decreases. The developed planar sensors were used for determination of cephalosporin antibiotics in model aqueous solutions, medicinal preparations and oral fluid.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>цефазолин</kwd><kwd>цефуроксим</kwd><kwd>цефтриаксон</kwd><kwd>потенциометрический сенсор</kwd><kwd>полианилин</kwd><kwd>наночастицы</kwd><kwd>лекарственные и биологические среды</kwd></kwd-group><kwd-group xml:lang="en"><kwd>cefazoline</kwd><kwd>cefuroxime</kwd><kwd>ceftriaxone</kwd><kwd>potentiometric sensor</kwd><kwd>polyaniline</kwd><kwd>nanoparticles</kwd><kwd>medicinal and biological media</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Makarova N. M., Kulapina E. G. New potentiometric screen-printed sensors for determination of homologous sodium alkylsulfates / Sens. Actuators, B. 2015. Vol. 210. P. 817 – 824. DOI: 10.1016/j.snb.2014.12.128.</mixed-citation><mixed-citation xml:lang="en">Makarova N. M., Kulapina E. G. New potentiometric screen-printed sensors for determination of homologous sodium alkylsulfates / Sens. Actuators, B. 2015. Vol. 210. P. 817 – 824. DOI: 10.1016/j.snb.2014.12.128.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Макарова Н. М., Кулапина Е. Г. Планарные сенсоры для определения полиоксиэтилированных соединений / Электрохимия. 2017. Т. 53. № 11. С. 1432 – 1439.</mixed-citation><mixed-citation xml:lang="en">Makarova N. M., Kulapina E. G. Planar sensors for determination of polyoxyethylated compounds / Russ. J. Electrochem. 2017. Vol. 53. N 11. P. 1266 – 1273. DOI: 10.1134/S1023193517110088.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Gornall D. D., Collyer S. D., Higson S. P. J. Investigations into the use of screenprinted carbon electrodes as templates for electrochemical sensors and sonochemically fabricated microelectrode arrays / Sens. Actuators, B. 2009. Vol. 141. N 2. P. 581 – 591. DOI: 10.1016/j.snb.2009.06.051.</mixed-citation><mixed-citation xml:lang="en">Gornall D. D., Collyer S. D., Higson S. P. J. Investigations into the use of screenprinted carbon electrodes as templates for electrochemical sensors and sonochemically fabricated microelectrode arrays / Sens. Actuators, B. 2009. Vol. 141. N 2. P. 581 – 591. DOI: 10.1016/j.snb.2009.06.051.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Alemayehu P. Washe, Pablo Lozano-Sбnchez, Diego Bejarano-Nosas, Ioanis Katakis. Facile and versatile approaches to enhancing electrochemical performance of screen printed electrodes / Electrochim. Acta. 2013. Vol. 91. P. 166 – 172. DOI: 10.1016/j.electacta.2012.12.110.</mixed-citation><mixed-citation xml:lang="en">Alemayehu P. Washe, Pablo Lozano-Sбnchez, Diego Bejarano-Nosas, Ioanis Katakis. Facile and versatile approaches to enhancing electrochemical performance of screen printed electrodes / Electrochim. Acta. 2013. Vol. 91. P. 166 – 172. DOI: 10.1016/j.electacta.2012.12.110.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Wang J., Tian B., Nascimento V. B., Agnes L. Performance of screen-printed carbon electrodes fabricated from different carbon inks / Electrochim. Acta. 1998. Vol. 43. N 23. P. 3459 – 3465. DOI: 10:1016/S0013-4686(98)00092-9.</mixed-citation><mixed-citation xml:lang="en">Wang J., Tian B., Nascimento V. B., Agnes L. Performance of screen-printed carbon electrodes fabricated from different carbon inks / Electrochim. Acta. 1998. Vol. 43. N 23. P. 3459 – 3465. DOI: 10:1016/S0013-4686(98)00092-9.</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Ji D., Liu Z., Liu L., et al. Smartphone-based integrated voltammetry system for simultaneous detection of ascorbic acid, dopamine, and uric acid with graphene and gold nanoparticles modified screen-printed electrodes / Biosens. Bioelectron. 2018. Vol. 119. P. 55 – 62. DOI: 10.1016/j.bios.2018.07.074.</mixed-citation><mixed-citation xml:lang="en">Ji D., Liu Z., Liu L., et al. Smartphone-based integrated voltammetry system for simultaneous detection of ascorbic acid, dopamine, and uric acid with graphene and gold nanoparticles modified screen-printed electrodes / Biosens. Bioelectron. 2018. Vol. 119. P. 55 – 62. DOI: 10.1016/j.bios.2018.07.074.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Charoenkitamorn K., Chaiyo S., Chailapakul O., Siangproh W. Low-cost and disposable sensors for the simultaneous determination of coenzyme Q10 and β-lipoic acid using manganese (IV) oxide-modified screen-printed graphene electrodes / Anal. Chim. Acta. 2018. Vol. 1004. P. 22 – 31. DOI: 10.1016/j.aca.2017.12.026.</mixed-citation><mixed-citation xml:lang="en">Charoenkitamorn K., Chaiyo S., Chailapakul O., Siangproh W. Low-cost and disposable sensors for the simultaneous determination of coenzyme Q10 and β-lipoic acid using manganese (IV) oxide-modified screen-printed graphene electrodes / Anal. Chim. Acta. 2018. Vol. 1004. P. 22 – 31. DOI: 10.1016/j.aca.2017.12.026.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Khater M., Escosura-Muniz A., Quesada-Gonzalez D., Merkoci A. Electrochemical detection of plant virus using gold nanoparticle-modified electrodes / Anal. Chim. Acta. 2019. Vol. 1046. P. 123 – 131. DOI: 10.1016/j.aca.2018.09.31.</mixed-citation><mixed-citation xml:lang="en">Khater M., Escosura-Muniz A., Quesada-Gonzalez D., Merkoci A. Electrochemical detection of plant virus using gold nanoparticle-modified electrodes / Anal. Chim. Acta. 2019. Vol. 1046. P. 123 – 131. DOI: 10.1016/j.aca.2018.09.31.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Ji D., Xu N., Liu Z., et al. Smartphone-based differential pulse amperometry system for real-time monitoring of levodopa with carbon nanotubes and gold nanoparticles modified screen-printing electrodes / Biosens. Bioelectron. 2019. Vol. 129. P. 216 – 223. DOI: 10.1016/j.bios.2018.09.082.</mixed-citation><mixed-citation xml:lang="en">Ji D., Xu N., Liu Z., et al. Smartphone-based differential pulse amperometry system for real-time monitoring of levodopa with carbon nanotubes and gold nanoparticles modified screen-printing electrodes / Biosens. Bioelectron. 2019. Vol. 129. P. 216 – 223. DOI: 10.1016/j.bios.2018.09.082.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Khaled E., Khalil M. M., Abed el Aziz G. M. Calixarene/carbon nanotubes based screen printed sensors for potentiometric determination of gentamicin sulphate in pharmaceutical preparations and spiked surface water samples / Sens. Actuators, B. 2017. Vol. 244. P. 876 – 884. DOI: 10.1016/j.snb.2017.01.033.</mixed-citation><mixed-citation xml:lang="en">Khaled E., Khalil M. M., Abed el Aziz G. M. Calixarene/ carbon nanotubes based screen printed sensors for potentiometric determination of gentamicin sulphate in pharmaceutical preparations and spiked surface water samples / Sens. Actuators, B. 2017. Vol. 244. P. 876 – 884. DOI: 10.1016/j.snb.2017.01.033.</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Saber A. L., Elmosallamy M. A., Killa H. M., Ghoneim M. M. Selective potentiometric method for determination of flucloxacillin antibiotic / J. of Taibah University for Science. 2013. Vol. 7. P. 195 – 201.</mixed-citation><mixed-citation xml:lang="en">Saber A. L., Elmosallamy M. A., Killa H. M., Ghoneim M. M. Selective potentiometric method for determination of flucloxacillin antibiotic / J. of Taibah University for Science. 2013. Vol. 7. P. 195 – 201.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Кулапина Е. Г., Дубасова А. Е., Кулапина О. И. Модифицированные твердоконтактные сенсоры для определения цефуроксима и цефалексина в лекарственных средствах и ротовой жидкости / Заводская лаборатория. Диагностика материалов. 2019. Т. 85. № 9. С. 5 – 14. DOI: 10.26896/1028-6861-2019-85-9-5-14.</mixed-citation><mixed-citation xml:lang="en">Kulapina E. G., Dubasova A. E., Kulapina O. I. Modified solid-contact sensors for determination of cefuroxime and cefalexin in medicines and oral fluid / Zavod. Lab. Diagn. Mater. 2019. Vol. 85. N. 9. P. 5 – 14 [in Russian]. DOI: 10.26896/1028-6861-2019-85-9-5-14.</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Кулапина Е. Г., Кулапина О. И., Анкина В. Д. Планарные потенциометрические сенсоры на основе углеродных материалов для определения цефотаксима и цефуроксима / Журн. аналит. химии. 2020. Т. 75. № 2. С. 231 – 237.</mixed-citation><mixed-citation xml:lang="en">Kulapina E. G., Kulapina O. I., Ankina V. D. Screen-Printed Potentiometric Sensors Based on Carbon Materials for Determining Cefotaxime and Cefuroxime / J. Anal. Chem. 2020. Vol. 75. N 2. P. 231 – 237. DOI: 10.1134/S1061934820020100.</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Машковский М. Д. Лекарственные средства. — М.: Новая Волна, 2006. — 1216 с.</mixed-citation><mixed-citation xml:lang="en">Mashkovskiy M. D. Medicinal agents. — Moscow: Novaya Volna, 2006. — 1216 p. [in Russian].</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Яковлев В. П., Яковлев С. В. Рациональная антимикробная фармакотерапия. — М.: Литтерра, 2007. — 784 с.</mixed-citation><mixed-citation xml:lang="en">Yakovlev V. P., Yakovlev S. V. Rational antimicrobial pharmacotherapy. — Moscow: Litterra, 2007. — 784 p. [in Russian].</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Кулапина Е. Г., Снесарев С. В., Кулапина О. И., Баринова О. В. Некоторые проблемы обеспечения избирательности и чувствительности определения антибиотиков в лекарственных и биологических средах: в кн. «Проблемы аналитической химии». Т. 16. «Фармацевтический анализ». Гл. 9. — М.: Аргамак-Медиа, 2013. С. 326 – 361.</mixed-citation><mixed-citation xml:lang="en">Kulapina E. G., Snesarev S. V., Kulapina O. I., Barinova O. V. Some problems of ensuring the selectivity and sensitivity of the determination of antibiotics in medicinal and biological environments / in the book «Problems of analytical chemistry». Vol. 16. «Pharmaceutical Analysis». Ch. 9. — Moscow: Argamak-Media, 2013. P. 326 – 361 [in Russian].</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Савинов С. С., Анисимов А. А., Дробышев А. И. Проблемы и оптимизация отбора образцов, их хранения и пробоподготовки при определении микроэлементного состава слюны человека / Журн. аналит. химии. 2016. Т. 71. № 10. С. 1063 – 1068.</mixed-citation><mixed-citation xml:lang="en">Savinov S. S., Anisimov A. A., Drobyshev A. I. Problems and optimization of sampling, storage, and sample preparation in the determination of the trace element composition of human saliva / J. Anal. Chem. 2016. Vol. 71. N 10. P. 1016 – 1021. DOI: 10.1134/S1061934816080128.</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Кондратенко С. Н., Стародубцев А. К., Золкина И. В. и др. Методики моделирования фармакокинетики некоторых лекарственных средств по динамике их распределения в слюне / Биомедицинская химия. 2014. Т. 60. № 2. С. 221 – 222.</mixed-citation><mixed-citation xml:lang="en">Kondratenko S. N., Starodubtsev A. K., Zolkina I. V, et al. Techniques of modeling of pharmacokinetics of some medicines on dynamics of their distribution in saliva / Biomed. Khim. 2014. Vol. 60. N 2. P. 221 – 222 [in Russian].</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Алексеев В. Г. Бионеорганическая химия пенициллинов и цефалоспоринов. — Тверь: Твер. гос. ун-т, 2009. — 104 с.</mixed-citation><mixed-citation xml:lang="en">Alekseev V. G. Bioinorganic chemistry of penicillin and cefalosporin. — Tver: Tver. gos. univ., 2009. — 104 p. [in Russian].</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Алексеев В. Г. Металлокомплексы пенициллинов и цефалоспоринов (обзор) / Хим.-фарм. журн. 2011. Т. 45. № 11. С. 31 – 48. DOI: 10.30906/0023-1134-2011-45-11-31-48.</mixed-citation><mixed-citation xml:lang="en">Alekseev V. G. Metal complexes of penicillins and cephalosporins (Review) / Pharm. Chem. J. 2012. Vol. 45. N 11. P. 679 – 697. DOI: 10.1007/s11094-012-0703-6.</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Tombeux J. J., Schaxtbroeck J., Brabanderh F. D., Goemtnne A. M. A Potentiometric Study of the Ag (I) Complexes of Some Sulphur Containing AminoAcids / Z. anorg. allg. Chem. 1984. Vol. 517. P. 235 – 240.</mixed-citation><mixed-citation xml:lang="en">Tombeux J. J., Schaxtbroeck J., Brabanderh F. D., Goemtnne A. M. A Potentiometric Study of the Ag (I) Complexes of Some Sulphur Containing AminoAcids / Z. anorg. allg. Chem. 1984. Vol. 517. P. 235 – 240.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Кулапина Е. Г., Снесарев С. В. Потенциометрические сенсоры на основе органических ионообменников тетраалкиламмония и комплексов серебра (I) с ампициллином, оксациллином, цефазолином / Журн. аналит. химии. 2012. Т. 67. № 2. С. 198 – 202.</mixed-citation><mixed-citation xml:lang="en">Kulapina E. G., Snesarev S. V. Potentiometric sensors based on organic ion exchangers of tetraalkylammonium and silver complexes with ampicillin, oxacillin, and cefazolin / J. Anal. Chem. 2012. Vol. 67. N 2. P. 163 – 167. DOI: 10.1134/S1061934811120069.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Будников Г. К., Евтюгин Г. А., Майстренко В. Н. Модифицированные электроды для вольтамперометрии в химии, биологии и медицине. — М.: Бином, 2009. — 331 с.</mixed-citation><mixed-citation xml:lang="en">Budnikov G. K., Evtyugin G. A., Maistrenko V. N. Modified electrodes for voltammetry in chemistry, biology and medicine. — Moscow: Binom, 2009. — 331 p. [in Russian].</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
