<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">zldm</journal-id><journal-title-group><journal-title xml:lang="ru">Заводская лаборатория. Диагностика материалов</journal-title><trans-title-group xml:lang="en"><trans-title>Industrial laboratory. Diagnostics of materials</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">1028-6861</issn><issn pub-type="epub">2588-0187</issn><publisher><publisher-name>ООО «Издательство «ТЕСТ-ЗЛ»</publisher-name></publisher></journal-meta><article-meta><article-id custom-type="elpub" pub-id-type="custom">zldm-393</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>Статьи</subject></subj-group></article-categories><title-group><article-title>Оценка содержания элементов при автоматическом качественном анализе вещества с использованием функции кросс-корреляции</article-title><trans-title-group xml:lang="en"><trans-title>Evaluation of the Element Content in an Automatic Qualitative Analysis of Substances Using a Cross-Correlation Function</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Панкратов</surname><given-names>С. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Pankratov</surname><given-names>S. V.</given-names></name></name-alternatives><email xlink:type="simple">Steve6305@gmail.com</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Лабусов</surname><given-names>В. А.</given-names></name><name name-style="western" xml:lang="en"><surname>Labusov</surname><given-names>V. A.</given-names></name></name-alternatives><email xlink:type="simple">noemail@neicon.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff xml:lang="ru" id="aff-1"><institution>Институт автоматики и электрометрии СО РАН; ООО «ВМК-Оптоэлектроника»</institution><country>Russian Federation</country></aff><aff xml:lang="ru" id="aff-2"><institution>Институт автоматики и электрометрии СО РАН; ООО «ВМК-Оптоэлектроника»; Новосибирский государственный технический университет</institution><country>Russian Federation</country></aff><pub-date pub-type="collection"><year>2017</year></pub-date><pub-date pub-type="epub"><day>01</day><month>01</month><year>2017</year></pub-date><volume>83</volume><issue>1</issue><fpage>132</fpage><lpage>138</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Панкратов С.В., Лабусов В.А., 2017</copyright-statement><copyright-year>2017</copyright-year><copyright-holder xml:lang="ru">Панкратов С.В., Лабусов В.А.</copyright-holder><copyright-holder xml:lang="en">Pankratov S.V., Labusov V.A.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://www.zldm.ru/jour/article/view/393">https://www.zldm.ru/jour/article/view/393</self-uri><abstract><p>В статье описаны метод и инструментарий автоматической оценки содержания элементов по одному спектру пробы. Наличие элементов в пробе определяется методом кросс-корреляционного качественного анализа, имеющим низкую вероятность ложного срабатывания и высокое быстродействие. Содержание найденный элементов рассчитывается с помощью метода появления и усиления спектральных линий, модифицированного для использования в автоматическом режиме в современных спектральный комплексах. Инструментарий требует настройки на конкретный комплекс по ранее полученным с его использованием результатам количественного спектрального анализа. Эффективность работы инструмента продемонстрирована на примере оценки содержания элементов основы геологических порошковых проб (Si, Ti, Al, Mg, Fe, Ca, Mn) по спектрам, полученным с помощью двух разных спектральный комплексов.</p></abstract><trans-abstract xml:lang="en"><p>A method and tools for automated evaluation of the element content in a sample using the only one sample spectrum is presented. The presence of elements in the sample is determined by qualitative cross-correlation analysis with a low probability of false alarm and high performance. The element content is calculated by modified spectral-line detection and enhancement method and adjusted to use in modern automated systems. The tool kit requires tuning to a particular spectral system using previously obtained results of quantitative spectral analysis for this system. The efficiency of the procedure is exemplified in evaluation of the content of matrix elements of geological powder samples of Si, Ti, Al, Mg, Fe, Ca, and Mn using two different analytical spectral systems.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>cross-correlation function</kwd><kwd>qualitative analysis</kwd><kwd>content evaluation</kwd><kwd>atomic emission spectra</kwd><kwd>multi-element solid-state detectors</kwd><kwd>функция кросс-корреляции</kwd><kwd>качественный анализ</kwd><kwd>оценка содержания</kwd><kwd>атомно-эмиссионные спектры</kwd><kwd>многоэлементные твердотельные детекторы</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Арнаутов Н. В., Глухова Н. М., Яковлева Н. А. Приближенный количественный спектральный анализ природных объектов. Таблицы появления и усиления спектральных линий. - Новосибирск: Наука, 1987. - 103 с.</mixed-citation><mixed-citation xml:lang="en">Арнаутов Н. В., Глухова Н. М., Яковлева Н. А. Приближенный количественный спектральный анализ природных объектов. Таблицы появления и усиления спектральных линий. - Новосибирск: Наука, 1987. - 103 с.</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Гаранин В. Г., Неклюдов О. А., Петроченко Д. В. и др. Программное обеспечение атомно-эмиссионного спектрального анализа. Программа «Атом» / Заводская лаборатория. Диагностика материалов. 2015. Т. 81. № 1. Ч. II. С. 121 - 127.</mixed-citation><mixed-citation xml:lang="en">Гаранин В. Г., Неклюдов О. А., Петроченко Д. В. и др. Программное обеспечение атомно-эмиссионного спектрального анализа. Программа «Атом» / Заводская лаборатория. Диагностика материалов. 2015. Т. 81. № 1. Ч. II. С. 121 - 127.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Панкратов С. В., Лабусов В. А., Неклюдов О. А. Качественный элементный анализ вещества с использованием функции кросс-корреляции / Аналитика и контроль. 2013. Т. 17. № 1. С. 33 - 40.</mixed-citation><mixed-citation xml:lang="en">Панкратов С. В., Лабусов В. А., Неклюдов О. А. Качественный элементный анализ вещества с использованием функции кросс-корреляции / Аналитика и контроль. 2013. Т. 17. № 1. С. 33 - 40.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Васильева И. Е., Шабанова Е. В. Дуговой атомно-эмиссионный анализ для исследования геохимических объектов / Заводская лаборатория. Диагностика материалов. 2012. Т. 78. № 1. Ч. II. С. 14 - 24.</mixed-citation><mixed-citation xml:lang="en">Васильева И. Е., Шабанова Е. В. Дуговой атомно-эмиссионный анализ для исследования геохимических объектов / Заводская лаборатория. Диагностика материалов. 2012. Т. 78. № 1. Ч. II. С. 14 - 24.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Черевко А. С., Морозова А. А. Исследование матричных помех в атомно-эмиссионной спектрометрии с дуговым аргоновым двухструйным плазмотроном / Заводская лаборатория. Диагностика материалов. 2017. Т. 83. № 1. Ч. II. С. 90 - 97.</mixed-citation><mixed-citation xml:lang="en">Черевко А. С., Морозова А. А. Исследование матричных помех в атомно-эмиссионной спектрометрии с дуговым аргоновым двухструйным плазмотроном / Заводская лаборатория. Диагностика материалов. 2017. Т. 83. № 1. Ч. II. С. 90 - 97.</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
