«Atom» software for atomic spectral analysis
https://doi.org/10.26896/1028-6861-2022-88-1-II-5-14
Abstract
The capabilities of the Atom software used in the spectral analytical equipment manufactured by the VMK-Optoelektronika company are presented. Spectral measurements using various sources — inductively coupled plasma, microwave plasma, arc and spark discharge in air or argon atmosphere, atomic absorption, etc. — are discussed. Procedures allowing the traceability of measurement results are described.
The calculation steps starting with calculation of the spectral line intensity to determination of the element content in the sample are briefly considered, as well as the estimation of statistical indicators and the metrological control of the measurement procedure according to GOST R ISO 5725. The advanced data export tools allow the transfer of results to external information systems, and, moreover, expand the functionality of the program through interaction with other applications. Various options for printing out using compact and extended presentations of results in the form of reports are available. The Atom software covers several methods of spectral analysis, including time-resolved spectrometry (scintillation, absorption, and analysis of non-metallic inclusions). Methods of qualitative and semi-quantitative analysis are offered in the form of separate additional tools. The Atom software distribution kit contains auxiliary information systems: a database of spectral lines, an alloy grade guide, a catalog of standard samples with certified elemental composition, and a database of the standard metrological characteristics of measurement methods. A distinctive feature of the Atom software is a well-thought-out user interface for the operation of any spectral-analytical equipment with high performance. The modern modular architecture of the program provides effective management of the project complexity and enables independent development of individual components using suitable tools.
About the Authors
V. G. GaraninRussian Federation
Viktor G. Garanin
630090, Novosibirsk, prosp. Akademika Koptyuga, 1-100
O. A. Neklyudov
Russian Federation
Oleg A. Neklyudov
630090, Novosibirsk, prosp. Akademika Koptyuga, 1-100
630090, Novosibirsk, prosp. Akademika Koptyuga, 1
D. V. Petrochenko
Russian Federation
Dmitry V. Petrochenko
630090, Novosibirsk, prosp. Akademika Koptyuga, 1-100
Z. V. Semenov
Russian Federation
Zakhar V. Semenov
630090, Novosibirsk, prosp. Akademika Koptyuga, 1-100
630090, Novosibirsk, prosp. Akademika Koptyuga, 1
P. V. Vashchenko
Russian Federation
Pavel V. Vashchenko
630090, Novosibirsk, prosp. Akademika Koptyuga, 1-100
630090, Novosibirsk, prosp. Akademika Koptyuga, 1
References
1. Labusov V. A., Garanin V. G., Shelpakova I. R. Multichannel analyzers of atomic emission spectra: Current state and analytical potentials / J. Anal. Chem. 2012. Vol. 67. N 7. P. 632 – 641. DOI:10.1134/S1061934812070040
2. Putmakov A. N., Popov V. I., Labusov V. A., Borisov A. V. New possibilities of modernized spectral instruments / Zavod. Lab. Diagn. Mater. 2007. Vol. 73. Special Issue. P. 26 – 28 [in Russian].
3. Labusov V. A., Garanin V. G., Zarubin I. A. New Spectral Complexes Based on MAES Analyzers / Inorg. Mater. 2018. Vol. 54. N 14. P. 1443 – 1448. DOI:10.1134/S0020168518140133
4. Garanin V. G., Neklyudov O. A., Petrochenko D. V., et al. «Atom» software for atomic spectral analysis / Zavod. Lab. Diagn. Mater. 2019. Vol. 85. N 1. Part II. P. 103 – 111 [in Russian]. DOI:10.26896/1028-6861-2019-85-1-II-103-111
5. Shabanova E. V., Bus’ko A. E., Vasil’eva I. E. Scintillation arc atomic emission analysis of powder samples using maes with high temporal resolution / Zavod. Lab. Diagn. Mater. 2012. Vol. 78. N 1. Part II. P. 24 – 33 [in Russian].
6. Shevelev G. A., Vasilenko L. I., Kamenskaya E. N., et al. Noble and rare metals in some coal deposits of Kazakhstan / Zavod. Lab. Diagn. Mater. 2019. Vol. 85. N 1. Part II. P. 38 – 45 [in Russian]. DOI:10.26896/1028-6861-2019-85-1-II-38-44
7. Dzyuba A. A., Labusov V. A., Vasil’eva I. E., et al. Analytical capabilities of «Grand-Potok» spectral system for the scintillation determination of gold and silver in geological samples / Analit. Kontrol’. 2017. Vol. 21. N 1. P. 6 – 15 [in Russian]. DOI:10.15826/analitika.2017.21.1.001
8. Bock D. N., Labusov V. A. Determination of Nonmetallic Inclusions in Metal Alloys by the Method of Spark Atomic Emission Spectroscopy (Review) / Inorg. Mater. 2019. Vol. 55. N 14. P. 1415 – 1427. DOI:10.1134/S0020168519140012
9. Babin S. A., Selyunin D. O., Labusov V. A. High-Speed Multichannel MAES Analyzers Based on BLPP-2000 and BLPP-4000 Photodetector Arrays / Inorg. Mater. 2020. Vol. 56. N 14. P. 1431 – 1435. DOI:10.1134/S0020168520140022
10. Dzyuba A. A., Labusov V. A., Babin S. A. Testing of MAES analyzers with BLPP-2000 and BLPP-4000 photodetector linear arrays in a «Grand-Potok» spectral system / Analit. Kontrol’. 2019. Vol.23. N 1. P. 35 – 42 [in Russian]. DOI:10.15826/analitika.2019.23.1.005
11. Labusov V. A., Boldova S. S., Selyunin D. O., et al. High-resolution continuum-source electrothermal atomic absorption spectrometer for simultaneous multi-element determination in the spectral range of 190 – 780 nm / J. Anal. At. Spectrom. 2019. Vol. 34. P. 1005 – 1010. DOI:10.1039/c8ja00432c
12. Pelipasov O. V., Labusov V. A., Put’makov A. N., et al. GRAND-MP — microwave plasma-atomic emission spectrometer / Analit. Kontrol’. 2019. Vol.23. N 1. P. 24 – 34 [in Russian]. DOI:10.15826/analitika.2019.23.1.004
13. Pelipasov O. V., Labusov V. A., Putmakov A. N. Atomic emission spectrometers with nitrogen microwave plasma. — Novosibirsk: Izd. NSTU, 2021. — 211 p. [in Russian]. http://www.vmk.ru/publications.html (accessed October 9, 2021).
14. Pelipasov O. V., Lokhtin R. A., Labusov V. A., Pelevina N. G. Analytical Capabilities of a Grand Spectrometer in Analysis of Solutions Using Inductively Coupled Plasma / Inorg. Mater. 2020. Vol. 56. N 14. P. 1446 – 1449. DOI:10.1134/S0020168520140113
15. Bulatov M. I., Kalinkin I. P. A practical guide to photometric methods of analysis. — Leningrad: Khimiya, 1986. — 432 p. [in Russian].
16. Pankratov S. V., Labusov V. A., Nekludov O. A., Vashchenko P. V. Automatic Wavelength Calibration of the Spectrometers with MAES Analyzers (Profiling) / Zavod. Lab. Diagn. Mater. 2015. Vol. 81. N 1. Part II. P. 128 – 134 [in Russian].
Review
For citations:
Garanin V.G., Neklyudov O.A., Petrochenko D.V., Semenov Z.V., Vashchenko P.V. «Atom» software for atomic spectral analysis. Industrial laboratory. Diagnostics of materials. 2022;88(1(II)):5-14. (In Russ.) https://doi.org/10.26896/1028-6861-2022-88-1-II-5-14