Measurements of the X-Ray Tube Focal Spot Using a Digital Flat Detector

Abstract

The size of the radiation source focal spot affects the image quality upon x-ray control of the objects. Prolonged use of x-ray tubes changes the size of the focal spot. Thus, both domestic and foreign regulatory documents contain requirements regarding a recurrent control of the focal spot of the radiation source which is rather time-consuming operation. Usually, the spot image obtained on a high contrast radiographic film is measured with a measuring magnifier or comparator. The method is inaccurate, since it suggests manual scanning ofthe image with a given step. Apossi bility of measuring the spot size using analysis of a digital radiographic image of the spot on a monitor of the digital radiographic unit and method of calculating adjustment factors are demonstrated.

About the Authors

E. I. Kosarina
ФГУП «ВИАМ»
Russian Federation


A. V. Stepanov
ФГУП «ВИАМ»
Russian Federation


A. A. Demidov
ФГУП «ВИАМ»
Russian Federation


O. A. Krupnina
ФГУП «ВИАМ»
Russian Federation


References

1. Каблов Е. Н. Авиакосмическое материаловедение / Все материалы. Энциклопедический справочник. 2008. № 3. С. 2 - 14.

2. Каблов Е. Н. Инновационные разработки ФГУП «ВИАМ» ГНЦ РФ по реализации «Стратегические направления развития материалов и технологий их переработки на период до 2030 года» / Авиационные материалы и технологии. 2015. № 1. С. 3 - 33.

3. Каблов Е. H., Морозов Г. А., Крутиков В. H., Муравская Н. П. Аттестация стандартных образцов состава сложнолегированных сплавов с применением эталона / Авиационные материалы и технологии. 2012. № 2. С. 9 - 11.

4. Каблов Е. Н. К 80-летию ВИАМ / Заводская лаборатория. Диагностика материалов. 2012. Т. 78. № 5. С. 79 - 82.

5. Каблов Е. Н. Современные материалы - основа инновационной модернизации России / Металлы Евразии. 2012. № 3. С. 10 - 15.

6. ISO 17636-2. Non-destructive testing of welds - Radiographic testing’s. Part 2: X- and gamma-ray techniques with digital detectors. 2013.

7. ISO 16371-1. Non-destructive testing - Industrial computed radiography with storage phosphor imaging plates. Part 1: Classification of systems. 2011.

8. ASTM E 2445-05. Standard Practice for Qualification and long-Term Stability of Computed Radiology Systems. 2010.

9. Степанов А. В. Методы рентгеновского неразрушающего контроля в производстве авиационных двигателей / Авиационные материалы и технологии. 2010. № 3. С. 28 - 32.

10. DIN EN 12543-1-1999. Non-destructive testing - Characteristics of focal spots in industrial x-ray systems for use in non-destructive testing. Part 1: Scanning method. 1999.

11. ГОСТ 22091.9-86. Приборы рентгеновские. Методы измерения размеров эффективного фокусного пятна. - М.: Госкомитет СССР по стандартам, 1986. - 15 с.

12. Косарина Е. И., Степанов А. В. Неразрушающий контроль / Большая российская энциклопедия. 2013. Т. 22. С. 487 - 488.

13. Korner M., Weber Ch. H. Advances in Digital Radiography: Physical Principles and System Overview / Radio Graphics. 2009. Vol. 27. P. 675 - 686.

14. Rowlands J. A. The physics of computed radiography / Phys. Med. Biol. 2002. Vol. 47. P. 123 - 166.

15. Fischbach F., Freund T., Pech M., et al. Comparison of indirect CsI/a:Si and direct a:Se digital radiography: an assessment of contrast and detail visualization / Acta Radiol. 2007. Vol. 44. P. 616 - 621.

16. Степанов А. В., Косарина Е. И., Саввина Н. А., Усачев В. Е. Макро- и микропористость в сплавах на основе алюминия и никеля, обнаружение ее рентгеноскопическими методами неразрушающего контроля / Авиационные материалы и технологии. 2012. № S. С. 423 - 430.

17. Косарина Е. И., Степанов А. В., Усачев В. Е. Рентгеноскопические установки для решения некоторых задач промышленной дефектоскопии / XIX Всероссийская науч.-тех. конференция «Современные методы и средства неразрушающего контроля и технической диагностики»: сб. тезисов докладов. - Самара, 2011. С. 245 - 246.

18. Майоров А. А. Цифровые технологии в неразрушающем контроле / Сфера Нефтегаз. 2009. № 9. С. 26 - 37.

19. Zscherpel U., Ewert U., Bavendiek K. Possibilities and Limits of Digital Industrial Radiology: The new high contrast sensitivity technique - Examples and system theoretical analysis. DIR 2007 / International Symposium on Digital industrial Radiology and Computed Tomography. Lyon. 2007. P. 3 - 27.


Review

For citations:


Kosarina E.I., Stepanov A.V., Demidov A.A., Krupnina O.A. Measurements of the X-Ray Tube Focal Spot Using a Digital Flat Detector. Industrial laboratory. Diagnostics of materials. 2016;82(10):29-32. (In Russ.)

Views: 595


ISSN 1028-6861 (Print)
ISSN 2588-0187 (Online)