Preview

Industrial laboratory. Diagnostics of materials

Advanced search

The Use of Tandem Mass Spectrometry of High-Resolution with Data-Dependent Acquisition for Verification of the Authenticity of Peptide and Protein Drugs

Abstract

The use of high-resolution mass spectrometry in data dependent acquisition mode is presented for assessing the authenticity of peptide and protein based drugs. The parameters of mass spectrometric detection (e.g., capillary potential and temperature, range of the detected ions, ion population, maximum ion injection time for MS/MS, ranges of the ion charge state and mass variation, duration of dynamic exclusion, impact energy, isolation width) are specified.

About the Authors

E. I. Berizovskaya
ФГУП «Научный центр «Сигнал»
Russian Federation


K. Y. Vasiliev
ФГУП «Научный центр «Сигнал»
Russian Federation


V. A. Maksimov
ФГУП «Научный центр «Сигнал»
Russian Federation


A. A. Ichalaynen
ФГУП «Научный центр «Сигнал»
Russian Federation


A. M. Antochin
ФГУП «Научный центр «Сигнал»
Russian Federation


V. F. Taranchenko
ФГУП «Научный центр «Сигнал»
Russian Federation


V. M. Goncharov
ФГУП «Научный центр «Сигнал»
Russian Federation


D. A. Mitrofanov
ФГУП «Научный центр «Сигнал»
Russian Federation


A. V. Udintsev
ФГУП «Научный центр «Сигнал»
Russian Federation


A. V. Aksenov
ФГУП «Научный центр «Сигнал»
Russian Federation


I. A. Rodin
Московский государственный университет им. М. В. Ломоносова
Russian Federation


O. A. Shpigun
ФГУП «Научный центр «Сигнал»
Russian Federation


References

1. Ушкалова Е. А. Проблемы фальсификации лекарственных средств: фокус на антимикробные препараты / Клиническая микробиология и антимикробная химиотерапия. 2005. Т. 7. №2. С. 167- 173.

2. Косенко В. В., Быков А. В., Мешковский А. П. Фальсифицированные лекарства - глобальная проблема / Вестник Росздравнадзора. 2009. № 3. С. 14 - 26.

3. Юмашева И. П. Фармацевтический рынок: проблема фальсификации лекарственных средств / Вестн. Томского гос. ун-та. 2011. Т. 16. №3. С. 897-901.

4. Aebersold R., Mann M. Mass spectrometry-based proteomics / Nature. 2003. Vol. 422. N 6928. P. 198 - 207.

5. Kalli A., Smith G., Sweredoski M., Hess S. Evaluation and optimization of mass spectrometric settings during data-dependent acquisition mode: focus on LTQ-Orbitrap mass analyzers / J. Proteome Res. 2013. Vol. 12. N 7. P. 3071 - 3086.

6. Zhang Y., Wen Z., Washburn M., Florens L. Effect of dynamic exclusion duration on spectral count based quantitative proteomics / Anal. Chem. 2009. Vol. 81. N 15. P. 6317 - 6326.

7. Andrews G., Dean R., Hawkridge A., Muddiman D. Improving proteome coverage on a LTQ-Orbitrap using design of experiments / J. Am. Soc. Mass Spectrom. 2011. Vol. 22. N4. P. 773 - 783.

8. Kim M., Kandasamy K., Chaerkady R., Pandey A. Assessment of resolution parameters for CID-based shotgun proteomic experiments on the LTQ-Orbitrap mass spectrometer / J. Am. Soc. Mass Spectrom. 2010. Vol. 21. N 9. P. 1606 - 1611.

9. Gaucher S., Taylor S., Fahy E., Zhang B., Warnock D., Ghosh S., Gibson B. Expanded coverage of the human heart mitochondrial proteome using multidimensional liquid chromatography coupled with tandem mass spectrometry / J. Proteome Res. 2004. Vol. 3. N 3. P. 495 - 505.

10. Kalli A., Hess S. Effect of mass spectrometric parameters on peptide and protein identification rates for shotgun proteomic experiments on an LTQ-orbitrap mass analyzer / Proteomics. 2012. Vol. 12. N1. P. 21-31.

11. Smith R., Loo J., Edmonds C., Barinaga C., Udseth H. New developments in biochemical mass spectrometry: electrospray ionization / Anal. Chem. 1990. Vol. 62. N 9. P. 882 - 899.


Review

For citations:


Berizovskaya E.I., Vasiliev K.Y., Maksimov V.A., Ichalaynen A.A., Antochin A.M., Taranchenko V.F., Goncharov V.M., Mitrofanov D.A., Udintsev A.V., Aksenov A.V., Rodin I.A., Shpigun O.A. The Use of Tandem Mass Spectrometry of High-Resolution with Data-Dependent Acquisition for Verification of the Authenticity of Peptide and Protein Drugs. Industrial laboratory. Diagnostics of materials. 2015;81(9):5-12. (In Russ.)

Views: 385


ISSN 1028-6861 (Print)
ISSN 2588-0187 (Online)